Performance Specifications:
MIL-PRF-44408 (with additional requirements.)
Weight:
Type I - 660 pounds less HMMWV mounting kit
(85 pounds) and pintle extension kit (50 pounds).

Payload:

4,300 pounds.

Overblast Protection:

2.0 PSI minimum.
EMI/RFI Shielding Capability::
Signal Effectiveness attenuation of 60 to 80 dB minimum (customer selectable) over the range of 150 kHz to 10 GHz for magnetic fields and plane waves when tested to ASTM Test Method ASTM E1851-97.
Heat Transfer:
Type I - .39 BTU/hr/sqft/F.
Lifting/Tiedown Rings:
Four (4) each dog-ear style, rated at 5,000 gross shelter payload IAW MIL-STD-209 requirements.

Towing Rings:
N/A
Roof Loads:

in excess of 40 PSF over entire roof, in excess of 660 pounds over any 2 sqft area.

Floor Loads:

65 PSF uniform load 1,000 pounds over any 2 sqft area 125 PSF point load.

Temperature:

Operational Range: -65F to +125F plus solar load Non-operational Range: -80F to +160F.